Steam Engineering Services
Steam System Engineering Disciplines
Inveno Engineering has vast experience in steam and condensate systems. We provide solutions to improve system operation, reliability, performance, and efficiency.
Update Boiler Control Systems
Many boiler controls are legacy systems that are no longer supported by the manufacturer. Older systems are also less effective at accurately and reliably controlling the operation of the boiler. Updating your boiler control system will improve operation and typically has a short payback due to the improvements in efficiency. Inveno is not affiliated with any manufacturer and can offer you an unbiased recommendation for the control package. Many facilities are also looking for ways to improve access to data. An updated boiler control package also provides access to operation and performance data.
High Quality Steam to Steam Turbines
Are you operating a steam turbine? Is your steam quality acceptable? High quality superheated steam is necessary for steam turbines to operate efficiently and reliably. Even if you are operating a saturated steam turbine, steam quality is essential for reliable operation. Inveno Engineering has the experience and knowledge to ensure that the correct condensate removal solution is implemented. Inveno’s engineers also utilize profiling software to determine the level of thermal expansion stresses that are tolerable to the installation.
Changes in Steam Load – Increased or Decreased
Is your plant expanding or has your steam demand declined? Many manufacturers are facing changes in market conditions that impacts the steam generation. Do you need to add another boiler or can you re-allocate thermal resources? Inveno has the experience to evaluate your system and load profile to identify the most effective approach to meet the changes in steam demand.
Enhance Desuperheater Operation
Many facilities generate superheated steam for a turbine installation but superheated steam does not work well for other manufacturing processes. Desuperheaters are used to return the steam to the saturated level. To provide reliable and effective service, desuperheaters must be specified and installed correctly. Inveno Engineering has the experience to evaluate your current desuperheater installations, identify deficiencies, and provide solutions to your desuperheater challenges.
Review Pressure Reducing Valve Stations
Many facilities have central steam pressure-reducing valve (PRV) stations to reduce the high pressure steam to a lower level for the manufacturing process. Are you having failures in your PRV station? Are your PRV stations configured correctly and code compliant? Inveno Engineering can review your PRV Stations to ensure that your PRV meets your reliability and compliance requirements. Inveno can also design you a PRV station and assist with the installation to ensure that your PRV solution supports 10 years of operation without failure.
Analyze Deaerator Systems
Three main functions are performed by deaerators: water is stored for the boiler, water is preheated, and non-condensable gases are scrubbed and discharged into the atmosphere. Deaerators must reduce the oxygen level to 7 PBB to prevent oxygen corrosion in the boiler and overall steam systems. We evaluate operation of the deaerator for its performance in removing the non-condensable gases. If a new deaerator is needed, we can also assist with this. Many items must be considered such as, which is the right choice for your operation? (Spray or tray?), what are the correct operating pressures and correct feedpump selection, and how much steam venting is necessary to guarantee proper operation?
When Installing a Boiler, Evaluate All Variables
When installing a boiler, plant personnel must consider a vast majority of possible variables. From operating pressure to fuel selection to flue gas recovery and heat recovery, there are many variables at stake. Our engineers will assist the plant personnel in the installation and the possible installation options. We ensure that the installed boiler will integrate smoothly with your existing systems, meet all required codes, and in turn, deliver the essential steam supply pressures..
Enhancing Product Quality through Optimal Steam Distribution Systems
Correct steam pressure, quantity, and quality are characteristics that a steam distribution system must deliver. Our engineers complete thorough engineering studies of your steam distribution systems to guarantee that each of the three areas are optimized for top product quality..
Improve Condensate System Efficiency and Safety
To achieve high steam cycle efficiency, your plant needs the highest steam pressure available that does not impact the process to be returned. These condensate systems are categorized as: Gravity, low-pressure, medium-pressure or high-pressure. It is essential that each type of system is applied properly. Inveno will help you determine the precise condensate pumps for your plant. In addition, we examine and analyze if your current condensate pump design meets standard code requirements to ensure for a safe and efficient operation.